Commodum nostrum:

minimal pixel dimensionis praesto

Reducitur optical crosstalk

Bonum uniformitas inter pixel ad pixel / ordinata ad ordinata

TiO2/BaSO4/ESR/E60

● Pixel Gap: 0.08, 0.1, 0.2, 0.3mm

euismod probatio praesto


Product Detail

Product Tags

Kinheng Offert variis Arrays pro fine Application

Praebere possumus CsI(Tl), CsI(Na), CdWO4, LYSO, LSO, YSO, GAGG, BGO scintilla vestit.Fundata in applicatione TiO2/BaSO4/ESR/E60 violenter adhibita materia repercussa pro pixel solitudo.Noster processui mechanicus servat minimam tolerantiam ad optimize corporis proprietates ordinatas possidet tolerantiam, dimensionem, minimam-crucem sermonem et uniformitatem etc.

Materiae Properties

Properties

CSI (Tl)

GAGG

CdWO4

LYSO

LSO

BGO

GOS (Pr/Tb) Ceramic

Density(g/cm3.

4.51

6.6

7.9

7.15

7.3~7.4

7.13

7.34

Hygroscopic

leviter

No

No

No

No

No

No

Lux relativa Output (% NaI (Tl)) (pro γ-radii)

45

158(HL)/ 132(BL)/79(FD)

32

65-75

75

15-20

71/ 118

Tempus (ns)

1000

150(HL)/ 90(BL)/48(FD)

14000

38-42

40

300

3000/600000

Afterglow@30ms

0.6-0.8%

0.1-0.2%

0.1-0.2%

N/A

N/A

0.1-0.2%

0.1-0.2%

Type ordinata

Linearibus et 2D

Linearibus et 2D

Linearibus et 2D

2D

2D

2D

Linearibus et 2D

Mechanica Design pro congregatione

Ex fine usu ordinatae convenerunt, multa genera consiliorum mechanicorum Kinheng obviam medicinae et industriae securitatis.

1D Lineae ordinatae maxime adhibentur ad inspectionem securitatis industriae, ut scanner, aviatio scanner, 3D scanner et NDT.Materia Possidet CsI (Tl), GOS: Tb/Pr Film.

GAGG:Ce, CdWO4 scintillator etc .

2D ordinata consuete adhibentur ad imaginationem (SPECT, PET, PET-CT, ToF-PET), SEM, gamma camera.Hae 2D ordinatae more cum SiPM ordinata sunt, PMT ordinata ad praelegendum.Kinheng 2D aciem praebet inter LYSO, CsI(Tl), LSO, GAGG, YSO, CsI (Na), BGO scintillator etc.

Infra sunt kinheng de more delineatas delineatas pro 1D et 2D ad industriam ordinatas.

Scintilla Array1

Kinheng linearibus ordinata

Scintilla Array2

Kinheng 2D array

Magna Parameter: (A, B, C, D in above Design)

Material genus A.1, sicut per petitionem a elit

A.2 Pixel amplitudo: pixel linearis ordinata magnitudo A, B, C & 2D pixel ordinata magnitudo A, C per petitionem accommodata sunt;

A.3 Pix: Linearibus ordinata A+B & 2D ordinata B, D adaptabilia per petitionem.

A.4 GAP: Minimam lacunam 0.1mm (tenaces inclusis) pro linearibus ordinata et 0.08mm (inclusa tenaces) pro 2D ordinata praebevimus.

A.5 ordinata crassitudine, sicut per petitionem.Kinheng elit praebet

A.6 Curatio pixel: politura, subtiliter vel speciali petitio praesto

Typical Pixel Size & Numeri

Materia

Typical pixel magnitudine

Typical numerus

Linear

2D

Linear

2D

CSI (Tl)

1.275x2.7

1x1mm

1x16

19x19

GAGG

1.275x2.7

0.5x0.5mm

1X16

8x8

CdWO4

1.275x2.7

3x3mm

1x16

8x8

LYSO/LSO/YSO

N/A

1X1mm

N/A

25x25

BGO

N/A

1x1mm

N/A

13X13

GOS (Tb/Pr) Ceramic

1.275X2.7

1X1mm

1X16

19X19

Minimam magnitudinem Pixel

Materia

Minima pixel magnitudine

Linear

2D

CSI (Tl)

0.4mm picem

0.5mm picis

GAGG

0.4mm picem

0.2mm picis

CdWO4

0.4mm picem

1mm picem

LYSO/LSO/YSO

N/A

0.2mm picis

BGO

N/A

0.2mm picis

GOS (Tb/Pr) Ceramic

0.4mm picem

1mm picem

Scintilla Forum Reflector Et Adhesive Parameter

Reflector

Crassitudo Reflector + Tenaces

Linear

2D

TiO2

0.1-1mm

0.1-1mm

BaSO4

0.1mm

0.1-0.5mm

ESR

N/A

0.08mm

E60

N/A

0.093mm

Scintilla Forum Application

Properties CSI (Tl) GAGG CdWO4 LYSO LSO BGO GOS (Tb/Pr) Ceramic
PET, ToF-PET   Ita   Ita Ita    
SPECT Ita Ita          
CT       Ita Ita Ita Ita
NDT Ita Ita Ita        
Bagger Scanner Ita Ita Ita        
Continens CATASTALTICUS Ita Ita Ita        
Gamma Camera Ita Ita          

Energy Consilium Testis

Scintilla Array3
Scintilla Array6
Scintilla Array4
Scintilla Array5

Inundationes Map

Scintilla Array7

Relativum lux Output Testis enim Linearibus Forum

Kinheng capacitatem habet ad comparationem lucis relativi output probationis pro LYSO/GAGG cum NaI (Tl) per PMT recitatum.

Uniformitas Guarantee

Kinheng singula elementa per petitionem eliget, levem outputam uniformitatem servare possumus intra ±5%, ± 10%, ± 15% per diversam postulationem.Singulae tabulae diligenter selectae sunt et probatae.

Scintilla Array

Interna vitia tentationis

Scintilla Array

Physica dimensio temptationis

CSI (Tl) Linearibus et 2D Forum

csi linearibus ordinata
csi (t) linearibus ordinata

GAGG Linear et 2D Forum

gagg linearibus ordinata
GAGG ACIES
GAGG linearis ordinata

CdWO4 Linearibus et 2D Forum

cdwo 2d
cdwo linearibus ordinata

LYSO Forum

lyso ordinata
LYSO ordinata

YSO Forum

linearibus ordinata

JSO Forum

Scintilla Array

BGO Forum

CSI scintillator array

GOS Linear Forum

gagg ordinata

  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis