PMT& Ambitus Integrated Detector, Scintillator Integratus Detector, Scintillatio cristallus detector
Product Introduction
Kinheng detectores scintillatores in PMT, SiPM, PD praebere possunt spectrometri radiophonii, dosimetri personalis, imaginationis securitatis et aliorum agrorum.
1. D series detector
2. ID series detector
3. Minimum navitas X-ray detector
4. SiPM serie detector
5. PD series detector
Products | |||||
Series | Exemplar No. | Descriptio | Input | Output | Connector |
PS | PS-1 | Electronic modulus cum nervum, 1"PMT | 14 Pins |
|
|
PS-2 | Electronic moduli cum nervum & altum / low potentia copia-2"PMT | 14Pins |
|
| |
SD | SD-1 | Detector.Integrated 1" NaI (Tl) and 1" PMT for Gamma ray |
| 14 Pins |
|
SD-2 | Detector.Integrated 2" NaI (Tl) and 2" PMT for Gamma ray |
| 14Pins |
| |
SD-2L | Detector.Integrated 2L NaI (Tl) and 3"PMT for Gamma ray |
| 14 Pins |
| |
SD-4L | Detector.Integrated 4L NaI (Tl) and 3"PMT for Gamma ray |
| 14 Pins |
| |
ID | ID-1 | Integrated Detector, cum 1” NaI (Tl), PMT, electronics moduli pro Gamma radius. |
|
| GX16 |
ID-2 | Integrated Detector, cum 2" NaI (Tl), PMT, electronics moduli pro Gamma radius. |
|
| GX16 | |
ID-2L | Integrated Detector, cum 2L NaI (Tl), PMT, electronics modulus pro Gamma ray. |
|
| GX16 | |
ID-4L | Integrated Detector, cum 4L NaI (Tl), PMT, electronics modulus pro Gamma radius. |
|
| GX16 | |
MCA | MCA-1024 | MCA, USB type-1024 Channel | 14 Pins |
|
|
MCA-2048 | MCA, USB type-2048 Channel | 14Pins |
|
| |
MCA-X | MCA, GX16 type Connector-1024~32768 canales in promptu sunt | 14Pins |
|
| |
HV | H-1 | HV OMNIBUS |
|
|
|
HA-1 | HV Module Novifacta |
|
|
| |
HL-1 | Princeps / Low intentione |
|
|
| |
HLA-1 | Princeps / Minimum Novifacta intentione |
|
|
| |
X | X-1 | Integrated detector-X ray 1” Crystal |
|
| GX16 |
S | S-1 | SIPM Integrated Detector |
|
| GX16 |
S-2 | SIPM Integrated Detector |
|
| GX16 |
Series detectorum SD in unam habitationem encapsulatam et PMT, quae incommodum hygroscopicum nonnullarum crystallorum possidet NaI (Tl), LaBr3:Ce, CLYC.Cum pacamentum PMT, materia geomagnetica protegens internus influentiam campi geomagnetici in detectore redegit.Locum pulsus est numeratio, vis spectri mensurae et radiorum dosis mensurae.
PS-Plug Socket amet |
Separati, Detector |
ID-Integrated Detector |
H. High intentione |
HL- Fixum Maximum / Low intentione |
AH- Novifacta High intentione |
AHL- Novifacta High / Low intentione |
MCA-Multi Channel Analyzer |
X-ray Detector |
S-SiPM Detector |
III "detectors design
III "ID detector iungo
Properties
ModelProperties | ID-1 | ID-2 | ID-2L | ID-4L |
Crystal Size | 1" | 2"&3" | 50x100x400mm/100x100x200mm | 100x100x400mm |
PMT | CR125 | CR105, CR119 | CR119 | CR119 |
Repono Temperature | -20 ~ 70℃ | -20 ~ 70℃ | -20 ~ 70℃ | -20 ~ 70℃ |
Operatio Temperature | 0~ 40℃ | 0~ 40℃ | 0~ 40℃ | 0~ 40℃ |
HV | 0~+1250V | 0~+1250V | 0~+1250V | 0~+1250V |
Scintillator | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 |
Operatio Temperature | ≤70% | ≤70% | ≤70% | ≤70% |
Inaedificata HV* | N/A | Libitum | Libitum | Libitum |
Lucrum Multiplier | 1~5 | 1~5 | 1~5 | 1~5 |
Energy Consilium | 6% ~ 8% | 6% ~ 8% | 6% ~ 8.5% | 6% ~ 8.5% |
Interface Type | GX16 | GX16BNC SHV | GX16 | GX16 |
Applicationem
Radialis dosis mensuraeprocessus quantitatis quantitatem radiorum cui vel obiectum exponitur.Est momenti aspectus salutis radialis et communiter in industriis ut in curis, energia nuclei et investigatione.Radiatio dosimetria critica est ad pericula sanitatis potentialis perpendendas, apta protocolla tutanda, et ad obsequia cum regulatoriis signis procuranda.Iusta vigilantia radiorum dosis adiuvat singulos ab inexpositione et impedimentis potentialibus adversis effectibus radiorum protegentibus.
Spectrum analysis, etiam spectroscopia seu analysin spectra quae nota est, scientia et ars technologiae est ad varias compositiones perscrutanda et examinanda significationum complexuum vel substantiarum quae in eorum proprietatibus spectris nituntur.Involvit mensuras et interpretationem energiae seu intensionis distributionum in diversis aequalitatibus vel frequentiis.