products

GOS:Pr crystal, GOS:Tb crystallus , GOS:Pr scintillator, GOS:Tb scintillatores

Description:

GOS scintillator ceramicus duo genera Ceramici diversa in iis GOS:Pr et GOS:Tb.Haec ceramica optimas notas habet ut lumen output altum, densum altum, humilis effectus postglow, late in imagine medicinae CT et industriae CT scanner inclusa medicinae, securitatis CT detectores.GOS Ceramicus scintillator altam conversionem efficientiam habet pro X-radiis, et eius temporis interitus (t1/10 = 5.5 nobis) brevis est, quae imaginationem brevi tempore repetitam cognoscere potest.Adhiberi potest non solum in instrumento imaginandi medicinae, sed etiam colore televisificae fistulae picturae.GOS scintillator ceramicus emissionem habet apicem spectris ad 470 ~ 900 um, quae bene congruit cum sensibilitate spectrali photodiodis pii (Si PD).


Product Detail

Product Tags

Commodum

Maximum lumen cede

Minimum interitus et humilis afterglow

● Flexibility to your design and purpose.

● Nullas toxicus aut ancipitia substantiae.

● Optime in humiditate resistentia.

Applicationem

Medical imaginatio

Medical CT

Industrial CT Scanner(NDT)

Properties

Parameter

GOS:Pr Ceramic

GOS:Tb Ceramic

Apicem Necem / nm

512

550

Systema

Poly-crystallina ceramic

Poly-crystallina ceramic

Perspicuus

Translucens

Translucens

Lux Output (photons/keV)

27

45

Tempus (ns)

3000

600000

Afterglow/@20ms

≤0.01%

≤0.03%

Coefficiens atomicus

60

60

Densitas (g/cm*3)

7.34

7.34

Hygroscopic

No

No

Mohs duritia

5

5

depictio producti

GOS:Pr/GOS:Tb est materia ceramica composita ex gadolinio oxysulfide, quod per praseodymium (Pr) vel terbium (Tb) quasi elementa doping.Praeclara scintillationis proprietatum, late scintillator materialis in instrumento imaginandi medicorum ut DELICIAE scanners adhibetur.Processus scintillationis implicat convertendi energiam photons vel particulas in lucem visibilem.

Cum excitantur radiorum incidentium, gadolinium atomorum in GOS:Pr/GOS:Tb photons emittunt, quae tunc a photodetectis deprehenduntur.Hic processus permittit subtilis imaginatio et detectio fontium radiorum.GOS:Pr/GOS:Tb notae sunt propter altitudinem luminis sui, brevem labem temporis et infimae sortis, ut celeriter et accurate deprehensionem radiorum praebeat.Habet etiam vim altam claudendi contra radios X-radios et gamma, quod efficacissimum est in applicationibus imaginandi medicinae.Super, GOS:Pr/GOS:Tb ceramicus est pretiosa scintillator materia, quae campum imaginandi medicae converterit, ducens ad diagnosin et morborum curationem efficaciorem.

Testis euismod

GOS:Pr PD collatio moduli probatio famae

1. Dimensiones

Item

Longitudo (mm)

Latitudo (mm)

Altitudo (mm)

Hiatus (mm)

Pixel

Reflecto (mm)

GOS

Competitores

25.4-0.1

3.0

1.25

0.2

1.575*2.9*1.2

0.05

GOS: Pr

Kinheng GOS: Tb

25.4-0.1

3.4

1.55

0.2

1.575*3.0*1.3

0.2

GOS: Tb

Kinheng GOS:Pr

25.4-0.1

3.4

1.55

0.2

1.575*3.0*1.3

0.2

GOS: Pr

GOSPr1
GOSPr2
GOSPr3

2. Alia doping

1.GOS:Tb PD MODUL 4 PCS.

1. Lux output probatio conditionis Voltage: 63 kv;Current: 0.33mA

S/N Pixel 1 Pixel 2 Pixel 3 Pixel 4 Pixel 5 Pixel 6 Pixel 7 Pixel 8 Pixel 9 Pixel 10 Pixel 11 Pixel 12 Pixel 13 Pixel 14 Pixel 15 Pixel 16 Mediocris
Tb -1 21088 21669 21782 21763 21614 21820 21754 21868 21931 21875 21840 21830 21670 21598 21705 21227 21689
Tb -2 20702 21948 22070 21824 21791 21734 21904 21585 21649 21747 21905 21888 21821 21737 21890 21316 21719
Tb -3 20515 21367 21701 21741 21394 21704 21811 21694 21743 21593 21600 21813 21880 21883 21679 20931 21565
Tb -4 20568 21407 21562 21719 21761 21875 21640 21610 21836 21804 21881 21560 21731 21717 21651 21431 21609

2. Uniformitas

S/N Pixel 1 Pixel 2 Pixel 3 Pixel 4 Pixel 5 Pixel 6 Pixel 7 Pixel 8 Pixel 9 Pixel 10 Pixel 11 Pixel 12 Pixel 13 Pixel 14 Pixel 15 Pixel 16 Max Min
Tb -1 -2.8% -0.1% 0.4% 0.3% -0.3% 0.6% 0.3% 0.8% 1.1% 0.9% 0.7% 0.6% -0.1% -0.4% 0.1% -2.1% 1.1% -2.8%
Tb -2 -4.7% 1.1% 1.6% 0.5% 0.3% 0.1% 0.9% -0.6% -0.3% 0.1% 0.9% 0.8% 0.5% 0.1% 0.8% - 1.9% 1.6% -4.7%
Tb -3 -4.9% -0.9% 0.6% 0.8% -0.8% 0.6% 1.1% 0.6% 0.8% 0.1% 0.2% 1.1% 1.5% 1.5% 0.5% -2.9% 1.5% -4.9%
Tb -4 -4.8% -0.9% -0.2% 0.5% 0.7% 1.2% 0.1% 0.0% 1.0% 0.9% 1.3% -0.2% 0.6% 0.5% 0.2% -0.8% 1.3% -4.8%

3. Afterglow: condicio probatio, intentione: 160kv;Current: 1 mA

Serial numerus

1ms

3ms

20ms

50ms

100ms

Tb -1

0.1115

0.093

0.132

0.0185

0.0187

Tb -2

0.1197

0.093

0.0165

0.0156

0.014

Tb -3

0.0895

0.0133

0.0119

0.0139

0.0156

Tb -4

0.1122

0.093

0.0156

0.0212

0.0211

4. Dimension

Item L/mm25.40.1 W/mm3.40.1 H/mm±0.05 Pixel 1.375±0.05 Nuduscrystal W 3.0±0.05 Totalis longitudo 25.0 ± 0.05 Gap0.2±0.05 latus pondero0.2±0.05 Top pondero0.2±0.05
Tb -1 25.39 3.363 1.52 1.386 2.998 24.978 0.188 0.19 0.199
Tb -2 25.397 3.337 1.53 1.387 2.994 24.98 0.186 0.171 0.192
Tb -3 25.392 3.352 1.53 1.389 3.003 24.98 0.167 0.167 0.196
Tb -4 25.396 3.358 1.53 1.385 2.996 24.978 0.186 0.177 0.224

2. GOS:Pr PD Module 4 PCS

1. Light output: tentatio conditionis voltage: 63 kv;current: 0.33mA

S/N Pixel 1 Pixel 2 Pixel 3 Pixel 4 Pixel 5 Pixel 6 Pixel 7 Pixel 8 Pixel 9 Pixel 10 Pixel 11 Pixel 12 Pixel 13 Pixel 14 Pixel 15 Pixel 16 Mediocris
Pr- 1 8922 9490 9483 9499 9535 9477 9405 9357 9230 9391 9388 9442 9346 9404 9381 9102 9366
Pr-2 8897 9257 9343 9351 9360 9200 9201 9329 9408 9385 9395 9333 9346 9413 9337 8845 9275
Pr -3 9041 9300 9302 9278 9362 9281 9252 9307 9178 9197 9342 9304 9261 9350 9265 8551 9223
Pr -4 8914 9416 9492 9455 9578 9491 9449 9404 9464 9490 9428 9323 9469 9490 9434 9039 9396

2. Uniformitas

Serial numerus pixel1 pixel2 pixel3 pixel4 pixel5 pixel6 pixel7 pixel8 pixel9 pixel10 pixel11 pixel12 pixel13 pixel14 pixel15 pixel16 Max Min
Pr- 1 -4.7% 1.3% 1.3% 1.4% 1.8% 1.2% 0.4% -0.1% - 1.4% 0.3% 0.2% 0.8% -0.2% 0.4% 0.2% -2.8% 1.8% -4.7%
Pr-2 -4.1% -0.2% 0.7% 0.8% 0.9% -0.8% -0.8% 0.6% 1.4% 1.2% 1.3% 0.6% 0.8% 1.5% 0.7% -4.6% 1.5% -4.6%
Pr -3 -2.0% 0.8% 0.9% 0.6% 1.5% 0.6% 0.3% 0.9% -0.5% -0.3% 1.3% 0.9% 0.4% 1.4% 0.5% -7.3% 1.5% -7.3%
Pr -4 -5.1% 0.2% 1.0% 0.6% 1.9% 1.0% 0.6% 0.1% 0.7% 1.0% 0.3% -0.8% 0.8% 1.0% 0.4% -3.8% 1.9% -5.1%

3. Afterglow: Temptatio conditionis intentione: 160kv;vena: 1 ma

Serial numerus

1ms

3ms

20ms

50ms

100ms

Pr- 1

0.093

0.031

0.0218

0.0234

0.0213

Pr-2

0.0419

0.0234

0.0202

0.0156

0.0234

Pr -3

0.093

0.093

0.0156

0.0167

0.0178

Pr -4

0.093

0.0202

0.018

0.018

0.031

4. Mensurae mensurae:

S/N Longitudo L/mm25.4-0.1 Width W/mm3.4-0.1 Altitudo L/mm±0.05 Pixel L 1.375±0.05 Pixel w 3.0±0.05 Summa legum 25.0± 0.05 Gap0.2±0.05 Sidereflector0.2±0.05 Endreflector0.2±0.05
Pr- 1 25.386 3.333 1.53 1.382 2.994 24.974 0.191 0.164 0.194
Pr-2 25.384 3.348 1.54 1.381 2.991 24.975 0.194 0.182 0.198
Pr -3 25.371 3.32 1.53 1.377 2.989 24.976 0.19 0.18 0.197
Pr -4 25.396 3.332 1.53 1.382 2.989 24.971 0.192 0.19 0.228

3. Aspectus / Dimensio comparationis:

GOS Pr detector
GOS Pr

  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis